One Radiator Not Getting Hot

Sep 18,2020

It can be hard to identify if there is an issue with a TRV because you are actually trying the address symptom rather than the cause, which could be many other things other than a faulty TRV. The most common issue for which TRVs can be the cause is that there is one radiator that is not getting hot, while all the others in the house are.


It is important to work systematically and rule out potential issues, starting with the easiest to address:




1.Bleed the radiator


2.Check that the TRV is fitted correctly: Most TRV’s are now universal and can be fitted on the flow or the return however older ones were not. Generally this leads to noisy bangs so you would probably know this, however it will take seconds to check that the arrows on the valve are pointing in the right direction (or both directions for a universal valve). Note that they might be on the wall side of the valve, so you may have to feel for them


3.Check that the TRV has not seized or got stuck: You will need to remove the top of the TRV which contains the thermostat and then check to see that the plunger that operates the valve can be depressed. (See below or the video for full details about how to do this). It might be necessary to oil the plunger with a little WD40 or similar lubricant. If it stays stuck a careful knock with a hammer might just free it. If this does not work, then the TRV is fault and the best thing to do it replace the valve


4.Check the thermostat: If the valve is freely moving, and the radiator is working when the thermostat cap has been taken off, but stops again when you replace it, the thermostat is likely to be the problem. They work with an expanding wax capsule which can sometime solidify and stops the TRV working. Change this and it should start to work again


5.Check the lock shield valve: By now you will be pretty sure that the issue is not with your TRV, so you need to check the valve at the other end of the radiator. This is the lock shield valve and should be left open all the time while the heating system is operating normally. Check that this is open by opening it a little further or by closing and opening it again


6.Airlock or blockage: It is likely that if both valves are function properly then the problem is either a blockage or an airlock. You could try to force the water through by closing of all the other radiators and then turning the heating on, using the room thermostat. This just might produce enough pressure to force through the blockage, if you are lucky


7.Drain the Radiator: At this point you will have to drain the radiator, which could resolve the issue, however once you have gone to the trouble of doing this it is probably worth removing and trying to flush the radiator out before refitting it or even replacing it with a new one (depending on the state of the old one).

If one of your radiators is not getting hot, then this process should help you get to the bottom of the issue, and certainly fin or rule out the TRV at the cause. However prevention is the best cure, and there is a little simple maintenance that can be done which will make sure that you

Latest News

Single-Master WiFi Architecture: Whole-Home App Control with One Thermostat

Jul 14,2026

Wireless RF Thermostat Technology for Hydronic Underfloor Heating Retrofits --- No Cables, No Mess, No Structural Damage

Jul 10,2026

How to Eliminate Thermostat Wiring Errors in Hydronic Underfloor Heating Systems

Jul 07,2026

Cleanroom VAV Control: Meeting ISO 14644 with Precision Pressure & Constant Airflow

Jun 01,2026

0-10V Damper Actuator Selection Guide: How to Choose the Best Actuator for Your VAV Controller

May 29,2026

How to Cut Heating Retrofit Labor Costs by 50%: The Business Logic of Cable-Free Technology

May 26,2026

Seeing is Saving: Utilizing Visualized Energy Data to Cut Heating Bills by 30%

May 22,2026

From Dumb Radiators to Smart Energy Assets: The Future of Grid-Interactive Heating

May 19,2026

Navigating the 2026 French Energy Subsidy: Why the SAS2024FHL-ZT5 is the Strategic Choice for Radiator Retrofits

May 17,2026

Multi-frame Supply Chain Advantage: Intercompatibility Testing with European Switch Panels

May 16,2026

Boiler Plus 2026 Guide: How OpenTherm Controls Achieve Compliance

May 06,2026

UK S-Plan & Y-Plan Dual Channel Thermostat – Complete Adapter’s Guide

May 05,2026

Zigbee 3.0 vs Wi-Fi vs Matter for HVAC – Which Protocol Should You Choose?

May 04,2026

OpenTherm vs On/Off Boiler Thermostat – The Ultimate Guide to Control Logic, Energy Savings & Boiler Plus Compliance

May 03,2026

The Buyer’s Guide: How to Select a Reliable HVAC Wiring Centre Supplier

May 02,2026
CONTACT US
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
Contact Us
SUBMIT NOW
Subscribe to Our Emails
Never miss SASWELL hot deals, news, and updates tailored for you.